Skip to main content
Concept

Retrofit & PAS 2035

How the UK's whole-home retrofit standard works, and what it means for your materials

4 min readUpdated November 2026

Save guide

What is PAS 2035?

PAS 2035 is the UK specification for assessing homes, designing energy retrofit work, and evaluating the results. It works alongside PAS 2030, which covers installation, testing, and handover of the measures. The current edition is PAS 2035:2023, which replaced the 2019 version on 30 March 2025.

Its central idea is that a home is a system of fabric, services, and occupants. A change to one part can affect the others. Better airtightness without better ventilation, for example, can lead to poor air quality, condensation, and mould.

When do you need it?

PAS 2035 can be applied to any domestic retrofit. It is required on some funded work, including delivery under the Warm Homes: Local Grant and Warm Homes: Social Housing Fund schemes. Privately funded projects may choose to follow it or have it written into their contract. Check the rules of any funding before you start.

It does not apply to work that is purely repair or like-for-like replacement and does not improve energy performance or ventilation. It does, however, treat good repair as the first step in any plan.

Who does what

Every PAS 2035 project needs a Retrofit Coordinator, who is responsible for overseeing it from start to finish. One person can hold more than one role if qualified for each and any conflict of interest is declared.

  • Retrofit Coordinator

    What they do
    Oversees the project, agrees outcomes with the client, and evaluates options
    Typical qualification
    Level 5 Diploma in Retrofit Coordination and Risk Management
  • Retrofit Assessor

    What they do
    Surveys the home, including condition, ventilation, and occupancy
    Typical qualification
    Certified domestic energy assessor or RICS surveyor
  • Retrofit Designer

    What they do
    Designs and specifies the measures and their junctions
    Typical qualification
    Depends on the project, up to an architect or chartered professional
  • Retrofit Installer

    What they do
    Installs the measures to PAS 2030 or MCS
    Typical qualification
    Certified for the measures being installed
  • Retrofit Evaluator

    What they do
    Checks whether the intended outcomes were achieved
    Typical qualification
    Qualified Retrofit Coordinator

Note. Older articles often describe risk paths A, B, and C. PAS 2035:2023 simplified the risk assessment process. Designer qualifications now depend on factors such as the number of interacting fabric measures, height, and whether the home is traditionally built.

The process, step by step

The main steps are the same for every project, with more added for traditional, protected, high-rise, and system-built homes.

  • Coordinator appointed and intended outcomes agreed, such as lower bills, better comfort, or less mould.
  • Whole-dwelling assessment, including a ventilation assessment and a list of defects to fix.
  • Improvement options evaluated, including payback and carbon cost-effectiveness.
  • Medium-term improvement plan prepared, even if only some work is happening now.
  • Retrofit design and specification, with details for corners, junctions, and edges.
  • Installation, inspection, testing, and commissioning.
  • Handover, with advice and documents for the occupants.
  • Basic evaluation within three months of handover, with further monitoring if needed.

Fabric first, and getting the order right

PAS 2035 describes a five-stage fabric first approach: fix defects and damp, carry out cheap and easy measures, improve insulation and airtightness while keeping adequate ventilation, install efficient heating, then add low or zero carbon energy. It also recognises exceptions, such as a boiler that has failed.

The medium-term plan matters because some measures make others harder later. External wall insulation, for instance, is easier if the roof overhang and window positions have been considered. Each stage should leave the next one possible.

Traditional and protected homes

PAS 2035 defines traditional construction as solid brick, stone, or earth walls built with moisture-permeable materials, usually before 1919, along with pre-1919 timber frame. These homes require an assessment of significance, and assessors and coordinators need an extra qualification in older and traditional buildings. A heritage impact assessment is required if a measure could affect something significant.

The standard says materials should match the building's moisture strategy, which may favour vapour-permeable and capillary-active materials. It also notes that wet finishes such as lime plaster can act as an air barrier while remaining vapour permeable.

Watch out. Internal wall insulation on solid walls carries real moisture risk. PAS 2035 notes that a standard condensation calculation may not be enough for exposed solid walls, so ask how the risk has been assessed.

What this means for choosing materials

A low-carbon product is only right if it works in the design. Designers must confirm that materials suit the building and each other, and follow relevant manufacturer instructions and standards.

TopicDetail
MoistureHow will the product behave in this build-up under BS 5250?
CompatibilityAre the insulation, membranes, tapes, renders, and plasters meant to work together?
JunctionsAre there details for reveals, eaves, and floor edges?
FireDoes the design keep the home's fire safety intact?
AirtightnessWhich layer forms the air barrier, and how will it be protected?
HandoverWhat maintenance and warranty information comes with the product?

Using Matera

Share your specification with suppliers and ask for installation details, compatible products, and test evidence that your Retrofit Designer can review. If you are planning in stages, save materials to a collection so you can return to the next stage of your plan.

Sources

Where the facts in this guide come from. Standards and guidance change, and some sources are suppliers or trade sites, so check the original before relying on a detail.