Skip to main content
Material

Recycled PET Acoustic Panels

How PET felt panels perform, how they are rated, and what to check before you buy

7 min readUpdated November 2026

Save guide

What are PET acoustic panels?

PET acoustic panels are boards of polyester fibre felt used to absorb sound on walls and ceilings, or hung as baffles and screens. PET (polyethylene terephthalate) is the plastic used for drinks bottles, and much of the recycled fibre in these panels comes from recovered bottles.

The fibres are usually thermally bonded. Heat fuses them together instead of a glue, so many panels are sold as 100% polyester with no added binder. Check this for the product you choose, because printed faces, backing layers, and fixing adhesives can add other materials.

Panels come in a wide range of thicknesses, from thin decorative sheets of around 9 mm to dense boards of 50 mm or more. They are light, easy to cut, and available in many colours, which is a large part of their appeal for offices, schools, and homes.

Absorption is not soundproofing

Acoustic panels absorb sound inside a room. They reduce echo and reverberation, which makes speech clearer and busy rooms calmer. Reverberation time depends on the room's volume and the total absorption of its surfaces, so adding absorption shortens it.

Sound insulation is a different job. It is about stopping sound passing between rooms, through walls, floors, and gaps. That depends mainly on mass, airtightness, and separating construction. UK school acoustic guidance notes that normal furnishing has no significant effect on sound insulation, but may reduce reverberation by providing absorption. The same logic applies to panels.

Watch out. Lightweight felt panels will not stop a neighbour hearing your music or block noise from the next office. If the problem is sound coming through a wall or floor, you need sound insulation, not absorption.

How acoustic performance is rated

Absorption is measured in a reverberation room to BS EN ISO 354. The results are given as a sound absorption coefficient at each frequency, from 0 (fully reflective) to around 1 (absorbs almost all of the sound that reaches it).

In the UK and Europe, BS EN ISO 11654 turns those results into a single weighted value, αw, and an absorption class from A to E. In North America, ASTM C423 gives the Noise Reduction Coefficient (NRC), which is the average of the values at 250, 500, 1000, and 2000 Hz. Both are useful shorthand, but neither tells you everything.

Thin panels mounted flat on a wall mainly absorb mid and high frequencies. Thicker panels, or panels with an air gap behind them, absorb more at low frequencies. This is why the same felt can carry very different ratings.

One manufacturer's data sheet shows this clearly. Its 25 mm panel is rated Class C with an NRC of 0.85, while the 50 mm version is Class A with an NRC of 1.00. At 125 Hz, the 25 mm panel absorbs 0.15 of the sound and the 100 mm panel absorbs 0.65.

Another supplier rates a 9 mm felt at NRC 0.80, but that test used a 200 mm air cavity behind the panel. Fixed directly to a wall, it would be expected to perform less well at low frequencies.

  • A

    0.90-1.00
    In plain terms
    Highest absorption
  • B

    0.80-0.85
    In plain terms
    High absorption
  • C

    0.60-0.75
    In plain terms
    Medium absorption
  • D

    0.30-0.55
    In plain terms
    Low absorption
  • E

    0.15-0.25
    In plain terms
    Very low absorption
  • Not classified

    0.00-0.10
    In plain terms
    Mostly reflective

Sound absorption classes under BS EN ISO 11654

  • Ask for the test report, not just the headline class or NRC.
  • Check the thickness and mounting used in the test, and whether it matches your installation.
  • Look at the values per frequency band if speech, music, or low-frequency noise is the main concern.
  • For schools, flats, and offices with performance targets, ask an acoustician to check the design.

Note. An absorption class only applies to the build-up that was tested. The overall depth of the system, including any air gap behind the panel, should always be stated with the class.

Recycled content claims

Recycled content varies between products, and many panels blend recycled and virgin polyester. One manufacturer gives an average of 58% recycled content and says the figure varies between colours, so the panel you pick may not match the headline number.

It also matters where the recycled fibre comes from. Post-consumer material, such as used bottles, has been through a consumer's hands. Pre-consumer material is factory waste diverted from another process. Both can count as recycled content, but they are not the same. See the Recycled Content Explained guide for how these figures are calculated.

  • Ask for the recycled content as a percentage by weight, for the exact product and colour.
  • Ask how much is post-consumer and how much is pre-consumer.
  • Ask what evidence backs the figure: an EPD, a third-party certificate, or only a supplier statement.

Fire performance

PET felt is combustible, so the reaction to fire class matters. Published examples for PET felt panels include B-s1, d0 and B-s2, d2 under BS EN 13501-1. Wood wool panels show a similar range, with B-s1, d0 for standard products and A2-s1, d0 for some specialist ranges.

Government guidance notes that the same material can achieve different classifications in different forms, so check that the test report covers your thickness, colour, substrate, and fixing method. Approved Document B also sets stricter lining classes for circulation spaces than for rooms.

In buildings other than dwellings, for example, it gives D-s3, d2 for small rooms, C-s3, d2 for other rooms, and B-s3, d2 for other circulation spaces. Check the current edition and volume for your building type.

UK school guidance also says free-hanging baffles should have the appropriate spread of flame classification, even though they are not part of the ceiling.

Watch out. Do not assume all PET felt has the same fire class. Check the classification document for the exact product and use, especially for corridors, stairs, schools, and buildings with flats.

Indoor air and fibres

Panels with no added binder have one less possible source of emissions, but low emissions still need evidence. Some manufacturers publish VOC test results, for example against the California CDPH method. Ask for emissions data for the exact product, and check any printed face, coating, or adhesive as well. See the VOCs and Indoor Air Quality guide for what the labels mean.

Fibre shedding is a newer question. Research on homes shows that textiles release microfibres into indoor air and that health effects are still uncertain. We have not found studies that measure fibre release from PET acoustic panels themselves, so there is no firm basis to say they are either a problem or not. A firm, well-finished surface and avoiding abrasion in high-contact areas are sensible precautions.

End of life

A panel made only of polyester can in principle be recycled back into fibre, and some suppliers describe their felt as fully recyclable. In practice, that depends on whether there is a collection route, whether the panel has been glued to a wall, and whether it has been printed, laminated, or mixed with other fibres.

Do not assume a take-back scheme exists. Ask the supplier what happens to offcuts on site and to the panels at the end of their life, and treat "recyclable" as a claim that needs a named route behind it.

Tip. Mechanical fixings, rails, or hanging systems make panels easier to remove, reuse, or recycle than adhesive fixed directly to the wall.

Natural alternatives

If you prefer a biobased option, several natural materials are used for acoustic panels and baffles. They are not automatically better. Some contain polyester binder fibres or cement, and their fire classes vary. One UK hemp insulation slab, for example, declares 60% hemp fibre and a 37.5% recycled content, so the rest is made of other fibres. Compare them on the same tests as PET.

  • Recycled PET felt

    Main input
    Recycled and virgin polyester fibre, thermally bonded
    What to check
    Recycled share and source, fire class for your use, emissions data, take-back route
  • Hemp acoustic baffles

    Main input
    Hemp fibre, often with a binder
    What to check
    Binder type and share, fire class, absorption at the mounting you will use
  • Cork wall panels

    Main input
    Cork granules, expanded or bonded
    What to check
    Absorption data, fire class, which some expanded cork boards give as Class E
  • Coir acoustic panels

    Main input
    Coconut husk fibre
    What to check
    Binder, fire treatment, absorption test report
  • Sheep's wool panels

    Main input
    Wool fibre, often with polyester or a binder
    What to check
    Moth and fire treatments, polyester share, fire class
  • Wood wool panels

    Main input
    Wood strands bound with cement
    What to check
    Fire class, often B-s1, d0 or A2-s1, d0, and the weight on fixings

Recycled PET panels compared with natural alternatives

Using Matera

Matera does not currently list recycled PET acoustic panels. If you buy them elsewhere, ask the seller for the absorption test report with thickness and mounting, the recycled content split, the reaction to fire classification for your use, VOC data, and a named take-back or recycling route.

To compare biobased options, browse the acoustic panels on Matera, including hemp acoustic baffles, cork wall panels, coir acoustic panels, sheep's wool, and wood wool panels. Ask suppliers the same questions so you can compare them fairly with PET.

Sources

Where the facts in this guide come from. Standards and guidance change, and some sources are suppliers or trade sites, so check the original before relying on a detail.