What Euroclasses mean, what Part B asks for, and how to specify timber, hemp, and natural insulation safely
5 min readUpdated November 2026
Save guideContents
Biobased materials are not automatically unsafe, and they are not automatically safe either. Many are combustible, which limits where they can go. Whether a design is acceptable depends on the classification of the actual product, the build-up it sits in, the height and use of the building, and its distance from the boundary.
"It's natural" and "it's fire treated" are not fire data. A specification needs a classification report or test evidence that matches the product and how it will be used.
Watch out. This guide is an introduction, not a fire strategy. It summarises guidance for England as of November 2026. Wales, Scotland, and Northern Ireland have their own guidance. Confirm the design with your building control body or a fire engineer.
These two terms are often confused, and a material can do well on one and poorly on the other. Heavy timber is a good example: it is combustible, but it can keep carrying load for a predictable time in a fire.
Reaction to fire
Fire resistance
A Euroclass has three parts. The letter describes combustibility, from A1 (non-combustible) to F (no performance determined). The s number describes smoke, from s1 (least) to s3 (most). The d number describes burning droplets, from d0 (none) to d2 (most). All three matter: B-s1, d0 and B-s3, d2 are not the same result.
The older national classes, such as Class 0, have been removed from Approved Document B for reaction to fire. If a product sheet only quotes them, ask for a current BS EN 13501-1 classification. Removal of national classes for fire resistance takes effect on 2 September 2029, subject to transitional arrangements.
These are starting points to help you ask the right questions. Results vary between products, so use the supplier's classification rather than this table.
Untreated timber cladding
Fire-retardant treated timber
CLT and heavy timber
Wood fibre insulation
Sheep's wool insulation
Cellulose insulation
Hempcrete and other plastered biobased walls
Straw bale
Typical behaviour. Always check the product's own test evidence.
Height is the main dividing line for dwellings. The table below summarises the main provisions in Approved Document B Volume 1 (Section 10). Other routes and exemptions exist, so treat it as a guide to the conversation with building control.
11m or less
B-s3, d2 or betterMore than 11m
A2-s1, d0 or betterRelevant building with a storey at 18m or more (regulation 7)
A2-s1, d0 or A1Approved Document B Volume 1, England. Heights refer to the storey or building measure defined in the document.
Note. Rules are under review. A Building Safety Regulator consultation on Approved Document B, which closed on 1 July 2026, covered external walls and the scope of the combustible materials ban. No outcome had been published when we last checked, so check the latest position on GOV.UK.
Exposed wall and ceiling linings have their own limits. In dwellings, most rooms and circulation spaces need C-s3, d2, small rooms up to 4m2 can use D-s3, d2, and other circulation spaces such as common areas in flats need B-s3, d2. This affects exposed CLT and timber boarding.
Thatch and wood shingles with no established test performance are treated as EROOF(t4). That normally means keeping them at least 6m from the relevant boundary, with further limits on larger buildings and terraces. Approved Document B also notes that closer distances can be considered where precautions such as those in the Dorset Model are used.
A product's rating does not automatically transfer to the finished wall. Cladding that reached a class in one test arrangement may behave differently over a different substrate or air gap. Fire barriers and cavity barriers matter too, particularly behind ventilated cladding.
Tip. Raise fire early. Changing a cladding or insulation late in a project can affect the wall build-up, moisture strategy, and budget at the same time.
Before you shortlist a product, ask the supplier for its BS EN 13501-1 classification report and details of the tested build-up. Keep these alongside the carbon data so that fire and sustainability are compared together.
Where the facts in this guide come from. Standards and guidance change, and some sources are suppliers or trade sites, so check the original before relying on a detail.